TM9-4310-396-13MAINTENANCE OF AIR FILTER ELEMENT3-5 MAINTENANCE OF AIR FILTER ELEMENT.This task covers:a. Inspection c. Serviceb. Removald. InstallationINITIALSETUPToolsEquipmentConditions:NoneEngine stopped, para. 2-6.8Materials/PartsSolvent, Dry Cleaning (Appendix E, item 2)Rag, Wiping (Appendix E, item 3).Filter Element (P/N 114250-12580)a. Inspection. Refer to PMCS Table 2-3.b. Removal.(1) Remove plain wingnut (1, Figure 3-2), seal washer (2), and access cover (3).(2) Remove filter element (4) from air cleaner case (5).c. Service.WARNINGDry cleaning solvent used to clean parts is potentially dangerous topersonnel and property. Clean parts in a well-ventilated area.Avoid inhalation of solvent fumes. Wear goggles or eye protectionwhen blowing solvent from parts. Air pressure should not exceed 30 psi.(2.1 Kg/cm2). Wear rubber gloves to protect skin. Wash exposed skinthoroughly. Do not smoke or use near open flame or excessive heat.Flash point of solvent is 100°F to 138°F (38°C to 59°C). Failure toobserve this warning may result in severe personal injury or death.(1) Remove buildup of dirt, grease, and debris.(2) Clean metal parts with clean, soft cloth and cleaning solvent.NOTEIf inside of filter element appears dirty or outside does not clean well,report to Unit maintenance.(3) Wipe outside of filter element using clean soft cloth.3-9