TM9-4310-396-13
MAINTENANCE OF AIR FILTER ELEMENT
3-5 MAINTENANCE OF AIR FILTER ELEMENT.
This task covers:
a. Inspection c. Service
b. Removal
d. Installation
INITIAL SETUP
Tools
Equipment Conditions:
None
Engine stopped, para. 2-6.8
Materials/Parts
Solvent, Dry Cleaning (Appendix E, item 2)
Rag, Wiping (Appendix E, item 3).
Filter Element (P/N 114250-12580)
a. Inspection. Refer to PMCS Table 2-3.
b. Removal.
(1) Remove plain wingnut (1, Figure 3-2), seal washer (2), and access cover (3).
(2) Remove filter element (4) from air cleaner case (5).
c. Service.
WARNING
Dry cleaning solvent used to clean parts is potentially dangerous to
personnel and property. Clean parts in a well-ventilated area.
Avoid inhalation of solvent fumes. Wear goggles or eye protection
when blowing solvent from parts. Air pressure should not exceed 30 psi.
(2.1 Kg/cm2). Wear rubber gloves to protect skin. Wash exposed skin
thoroughly. Do not smoke or use near open flame or excessive heat.
Flash point of solvent is 100°F to 138°F (38°C to 59°C). Failure to
observe this warning may result in severe personal injury or death.
(1) Remove buildup of dirt, grease, and debris.
(2) Clean metal parts with clean, soft cloth and cleaning solvent.
NOTE
If inside of filter element appears dirty or outside does not clean well,
report to Unit maintenance.
(3) Wipe outside of filter element using clean soft cloth.
3-9