TM 9-4310-397-14
Table 4-1. Preventive Maintenance checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
22 -
g. Connect any loose hoses per tags.
Cont
Remove tags.
h. Check compressor oil level.
i. Close access doors (107).
SECTION IV MANDATORY REPLACEMENT PARTS
The following table includes all items that must be replaced during PMCS whether they have failed or not. The table
reflects the interval at which these items must be replaced whether hardtime maintenance or on condition maintenance.
ITEM
PART
NO.
NUMBER
NSN
NOMENCLATURE
QTY
1
MS35338-48
5310-00-584-5272
Lock Washer
8
2
R17, 86810, 51459, PF-881,
2940-01-080-3861
Compressor Oil Filter
1
PH-977A
3
T20215
5330-00-340-5374
Gasket
1
4
MS35338-44
5310-00-582-5965
Lock Washer
4
5
DD14941
6685-01-378-3468
Thermostat
1
6
R106796
5330-01-388-8523
O-Ring (Gasket)
1
7
AR50041
2910-00-100-3354
Fuel Filter
1
8
T19044
2940-00-007-4791
Engine Oil Filter
1
9
DVC-0168-3, 48772
4310-00-883-0512
Separator Element
1