TM 9-4310-397-14
Table 4-1. Preventive Maintenance checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
19-
f. Install new thermostat (99) (item
Cont
5, section IV, chapter 4), new
gasket (98) (item 3, section IV,
chapter 4), cover (97), and two
hex head screws (96).
g. Pour coolant drained in step b.
above back into radiator.
h. Clean any coolant spills with a
wiping rag (item 2, section II,
appendix E).
i. Close access doors (95).
20
1200
Exterior Rear,
Service the radiator by draining and
Service
Radiator
flushing per the following:
Hours or 2
Years
a. Remove four hex head screws
(101) and lock washers (102).
Open airblock (103). Discard lock
washers.
b. Place pan (section II, appendix D)
under drain cock (104).
c. Remove radiator fill cap (105).
4-36