TM 9-4310-397-14
Table 2-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
(2) If operating at temperatures
below 0° F (-18° C), use pre-mixed
antifreeze (item 8, section II,
appendix E) and do not dilute it.
INTERIOR
WARNING
The fuels in this compressor are
highly explosive. Do not make
or use open flame when
performing maintenance.
Flames and explosion could
result in severe personal injury
or death.
7
Before
Fuel Tank
Inspect fuel tank (10).
a. Check for cuts, dents, broken
Fuel tank is cut, cracked,
welds, cracks, or leaks.
has broken welds, or class
III leak is found.
b. Service fuel tank by checking fuel
Fuel level is less than 1/4
level. If level is less than 1/4
tank.
tank, top off with fuel (item 19,
section II, appendix E) or (item 20,
section II, appendix E).
2-11