TM 9-4310-397-14
Table 2-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
50
Weekly
Batteries
Inspect battery (58) for cracks,
Battery cracked, terminal
damaged terminal, and leaks.
damaged, or any evidence
of leaking.
51
Weekly
Starter
Inspect starter (59) for any evidence of
Starter shows evidence of
overheating such as discoloration of overheating.
casing or burn marks.
52
Weekly
Relay Reset Switch
Inspect relay switch (60) case for cracks Relay switch case is
and operate to check for binding when cracked or binds when
reset.
reset.
2-24