TM 9-4310-397-14
SECTION III OPERATION UNDER USUAL CONDITIONS
2-4. ASSEMBLY AND PREPARATION FOR USE.
Notify unit maintenance for assistance with unloading, unpacking, and initial assembly/preparation for use.
2-5. OPERATING PROCEDURES.
Usual operating conditions are when the ambient temperature is between 40° F and 100° F (5° C and 38° C).
a.
Prior to Operating. Place unit on a fairly level surface with a maximum angle of 15° in any direction. Unit should
be located in an area as free of dust and dirt as possible.
(1)
Perform all of the BEFORE PMCS outlined in table 2-1.
(2)
Connect hose reel hose to air tools or system for task to be performed. Additional air hoses connected to
service outlets may also be used.
b.
Starting Procedure. (See Figure 2-3.)
WARNING
Operating the unit in a building or any enclosed area without the exhaust gases piped outside can result
in serious illness or death.
CAUTION
Operating the equipment unattended for prolonged periods of time can result in serious
damage to the unit.
(1)
Open hose reel valve (1) and double discharge valve (2) as necessary.
(2)
Turn COMPRessor UNLOADER AND IDLE CONTROL knob (3) clockwise until it stops.
(3)
Pull IGNITION-START switch (4) out to first (run) position.
NOTE
Engine water temperature and compressor oil temperature must be at or below normal
readings before resetting relay reset switch.
(4)
Push relay reset switch (5).
CAUTION
Operating the engine with low or no oil pressure can cause serious equipment damage.
(5)
Pull IGNITION-START switch (4) all the way out to engage starter. Crank engine for three seconds to
check for binding, then release switch.
2-27