Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
15 -
(20)
Install new separator element
Cont
(75) (item 9, section IV,
chapter 4).
CAUTION
Using standard commercial
hex head screws in place of
high
tensile
hex
head
screws to secure the oil
separator cover can result
in damage or failure of the
equipment
during
operation. The original, or
correct replacement, high
tensile hex head screws
must be used to secure the
oil separator cover to meet
ASME
standards
for
pressure vessels.
(21)
Install oil separator cover
(71) and align match marks.
Install eight hex head screws
(73) and new lock washers
(74) (item 1, section IV,
chapter 4).
(22)
Connect any loose hoses per
tags. Remove tags.
(23)
Close access doors (70).
(24)
Wrap antiseize tape (item 1,
section II, appendix E)
around the drain valve plug
(66)threads.
(25)
Clean the drain valve (67)
with a wiping rag (item 2,
section II, appendix E) and
install the drain valve plug
(66).
(26)
Install approximately 20
Oil level not visible in
quarts lubricating oil (item 4,
filler pipe elbow.
section II, appendix E) or
until oil is visible in elbow.
4-30