TM 9-4310-397-14Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - ContinuedLocationItem No.IntervalProcedureNot Fully Mission Capable If:Item toCheck/Service15 -(20)Install new separator elementCont(75) (item 9, section IV,chapter 4).CAUTIONUsing standard commercialhex head screws in place ofhigh tensile hex headscrews to secure the oilseparator cover can resultin damage or failure of theequipment duringoperation. The original, orcorrect replacement, hightensile hex head screwsmust be used to secure theoil separator cover to meetASME standards forpressure vessels.(21)Install oil separator cover(71) and align match marks.Install eight hex head screws(73) and new lock washers(74) (item 1, section IV,chapter 4).(22)Connect any loose hoses pertags. Remove tags.(23)Close access doors (70).(24)Wrap antiseize tape (item 1,section II, appendix E)around the drain valve plug(66)threads.(25)Clean the drain valve (67)with a wiping rag (item 2,section II, appendix E) andinstall the drain valve plug(66).(26)Install approximately 20Oil level not visible inquarts lubricating oil (item 4,filler pipe elbow.section II, appendix E) oruntil oil is visible in elbow.4-30
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business