TM 9-4310-397-14
Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
(11) Operate the compressor under
normal conditions for 40 to 60
hours. This will allow the
oil/solvent mixture sufficient
time to dissolve and suspend
the varnish in the system.
(12) Check that pan (section II,
appendix D) is under pipe
end.
(13) Shut down the compressor and
while the oil is still hot,
open drain valve (67) and
wait for all lubricating
oil/solvent mixture to drain
out. Contact your local
environmental officer for
guidance on how to properly
dispose of lubricating
oil/solvent mixture in
accordance with local
regulations.
(14) Close drain valve (67) and
remove pipe.
(15) Carefully remove and discard
oil filter (64).
(16) Open access doors (70).
(17) Tag (item 18, section II,
appendix E) and disconnect
hoses as necessary to remove
oil separator cover (71).
(18) Match mark the oil separator
cover (71) with the oil
separator tank (72). Remove
eight hex head screws (73),
lock washers (74), and oil
separator cover. Discard lock
washers.
(19) Remove and discard
separator element (75).
4-29