TM 9-4310-397-14
Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
15 -
(2) Remove drain valve plug
Cont
(66).
(3) Install a pipe (section II,
appendix D) into drain valve
(67).
(4) Place a pan (section II,
appendix D) under pipe end.
(5) Open drain valve (67) and
wait for all lubricating oil to
drain out. Contact your local
environmental officer for
guidance on how to properly
dispose of lubricating oil in
accordance with local
regulations.
(6) Close drain valve (67).
(7) Install a mixture of two quarts
Thermo-Solve concentrate
(item 16, section II, appendix
E) and approximately 18
quarts lubricating oil (item 4,
section II, appendix E).
(8) Check condition of preformed
Preformed packing
packing (68). Replace if
damaged.
damaged.
(9) Clean the adapter (69) with
a wiping rag (item 2, section
II, appendix E) and install oil
filler cap (65).
(10)Install new compressor oil
filter (64) (item 2, section IV
chapter 4).
4-28