TM
5-4310-350-14
Figure 5-4. Electric motor compressor, cleaning, V-belt
and installation.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. Remove attaching hardware and remove V-belt guard.
C.
Loosen motor mounting bolts, slide motor forward towards compressor and remove V-belts.
d. Tag and diseconnect electric leads.
e. Remove mounting bolts and remove the electric motor and disassemble using figure 53 as a
guide.
(1) Remove setscrew (5) pulley (6) and key (7).
(2) Remove four bolts (10) shaft end, end shield (13) opposite shaft end, end shield (11)
shaft end hearing (14) opposite shaft end bearing (12) spacer bearing (15) fan (16) rotor (17)
stator with frame (18) and base (19).
WARNING
Dry cleaning solvent PD-680, used to clean parts is Potentially dangerous to personnel and
property. Do not use near open flame or excessive heat. Flash point of solvent is 100 F.
-- 138 F.
(3) Clean all parts
except rotor, bearings and stator in dry cleaning solvent P-D-680 and
wipe dry with a lint free
cloth.
(4) Use compressed
air to clean dust and dirt off rotor, bearings, and stator, then wipe with
cleaning solvent PD-680.
a cloth dampened in dry