TM 5-4310-354-14
(Figure
4-34
Sheet
1
of
7)
(Figure
4-34
Sheet
2
of
7)
(Figure
4-34
Sheet
3
of
7)
(Figure
4-34
Sheet
4
of
7)
(Figure
4-34
Sheet
5
of
7)
(Figure
4-34
Sheet
6
of
7)
(Figure
4-34
Sheet
7
of
7)
TS5-4310-354-14/4-34 (1)
A RESTRICTION INDICATORS, PANEL LAMP, AND LAMP SWITCH
RESTRICTION INDICATORS
PANEL LAMP AND SWITCH
REMOVAL
REMOVAL
STEP 1.
UNSCREW AND REMOVE RESTRICTION
STEP 1.
DISCONNECT WIRE ASSEMBLIES FROM
INDICATORS
FROM
INSTRUMENT
LAMP SWITCH.
PANEL.
STEP 2.
REMOVE JAM NUT AND LOCK WASHER
STEP 2.
AS
NECESSARY,
UNSCREW
AND
AND REMOVE PANEL LAMP ASSEMBLY.
REMOVE SAFETY FILTER FITTING.
STEP 3.
REMOVE NUT, INDICATING PLATE, AND
LAMP SWITCH.
INSTALLATION
INSTALLATION
STEP 1.
INSTALL LAMP SWITCH AND INDICATING
STEP 1.
AS NECESSARY, INSTALL SAFETY
PLATE ON INSTRUMENT PANEL AND
FILTER FITTING WITH FILTER END
SECURE WITH NUT.
TOWARD THE INDICATOR.
STEP 2.
INSTALL PANEL LAMP ASSEMBLY ON
STEP 2.
INSTALL RESTRICTION INDICATOR IN
INSTRUMENT
PANEL
WITH
LENS
VERTICAL POSITION ON INSTRUMENT
OPENING
FACING
THE
GAUGES.
PANEL
SECURE WITH LOCK WASHER AND JAM
NUT.
STEP 3.
PRESS RESET BUTTON ON TOP OF
INDICATOR TO SHOW GREEN IN
STEP 3.
CONNECT WIRE ASSEMBLIES TO LAMP
INDICATING WINDOW.
SWITCH. (REFER TO WIRING DIAGRAM,
Figure 4-34. Instrument panel controls, instruments, and gauges, removal and installation (sheet 1 of 7).
4-65