TM 5-4310-369-14
Section III. MAINTENANCE PROCEDURES
c. If leak is found in fuel tank (2), report to next higher
General.
echelon for maintenance.
Instructions in this section are published for the informa-
d. Clean fuel tank strainer (6).
tion and guidance of the operator to maintain the air cor-
e. Check fuel tank draincock closed (3).
pressor.
f. Check fuel tank vent valve (4) for security and proper
Fuel Tank, Lines and Fittings
operation.
a. Check all fittings for leaks.
g. Check fuel tank fuel level gage (5) for free operation
b. Check fuel tank cap gasket for leaks and replace if
and gasket for leaking.
necessary.
h. Check fuel line strainer (7) for water or dirt, clean
if contaminated.