TM 5-4310-369-14
c. Testing. To test air receiver for leaks, pressurize to
d. Installation.
100 psi (7.03 kg/sq cm) with compressed air and check all
joints and welds with soapy water or submerge complete
installing bolts (27) and nuts (24).
tank in water. To test damaged tank it is necessary to test
(2) Install hose connectors (16 and 18), hose (16)
with hydrostatic pressure making sure all air has been re-
and inflator gage (17).
moved from air receiver. Test to a pressure of 300 psi
(3) Attach fittings (12), tee (10) and air pressure
(21.1 kg/sq cm). If any leaks appear, replace tank.
gage (3).
(4) Attach unloader valve (2) and safety and relief
WARNING
valve (4).
(5) Install draincock (5).
Do not weld repair air receiver tank.