T M 5-4310-375-14
Table 2-1. Operator/Crew Preventive Maintenance Checks and Services - Continued
EQUIPMENT IS NOT
ITEM TO BE
INTERVAL
ITEM
PROCEDURE
READY/AVAILABLE
IF:
W
INSPECTED
M
D A
B
NO.
for gauge replacement or pressure
switch adjustment.
Globe valve sticking,
Check operation of globe valve (9,
Air hose (16,
6
cuts or breaks in air
Check air hose (16) for cuts and
hose, or inflator gauge
Inflator gauge
does not operate.
breaks. Examine all fittings for
visual damage. Report all defects
Globe valve (9,
to Organizational Maintenance
for repair or replacement.
After operation and at least once
Receiver drain (11,
7
each week open receiver drain (11,
lated condensate. Check to make
certain drain cock closes and seats
properly. If drain cock leaks or is
damaged, notify Organizational
Maintenance for replacement.
Any malfunction of
Check operation of safety valve (6,
Safety valve (6,
8
safety valve.
located on end of valve until air
escapes from receiver tank. Re-
lease ring; valve should reseat
stopping escaping air. If valve does
not relieve air pressure in tank, or
does not reseat, notify Organiza-
tional Maintenance for replacement.
9
Air compressor
of operation (every 500 hours
thereafter). Drain while oil is
warm. Place a container below
cock (17) and remove filler
cap (12). When oil flow stops,
close oil drain cock (17), Fill
compressor with SAE 30 weight
oil to level of center mark on
sight gauge (7). Capacity of
compressor frame is 1-1/2 quarts
(1.4 liters). Refer to paragraph
3-2 for lubrication instructions.
2-5