TM 5-4310-378-14
(2) Inspect for leaks.
(3) Inspect for dents or other damage.
Replacement.
( 1 ) Open drain valve and unscrew it from bottom of air tank.
( 2 ) Obtain replacement drain valve and screw it into bottom of air tank.
This task covers:
a. Inspection
b.
Replacement
9/16-in. Wrench
Tools:
Materials:
S o l v e n t , Dry cleaning (Appendix E, item 2)
Gage, Pressure
Equipment Condition:
P r e s s u r e in air tank.
Ignition switch pushed in (Table 2-1, 8)
a. I n s p e c t i o n .
D r y Cleaning Solvent
(Stoddard Solvent)
P-D-680
C o m b u s t i b l e - do not use near open flames, near welding areas,
o r on hot surfaces.
P r o l o n g e d or repeated contact of skin with liquid can cause
d e r m a t i t i s . Repeated inhalation of vapor can irritate nose and
t h r o a t and can cause dizziness.
I f any liquid contacts skin or eyes, immediately flush affected
area thoroughly with water. Remove solvent-saturated
c l o t h i n g . If vapors cause dizziness, go to fresh air.
W h e n handling liquid or when applying it in an air-exhausted,
partially covered tank, wear approved gloves.
W h e n handling liquid or when applying it at an unexhausted,
uncovered tank or workbench, wear approved respirator,
g o g g l e s , and gloves.
(1)
U s e brush, rag, and solvent as necessary to clean pressure gage for inspection.
I n s p e c t for leaks.
(2)
I n s p e c t for cracked glass.
(3)
3-61