TM 5-4310-379-14
3-35. Battery and Cables (Cont).
b.
Replace. (figure 3-46)
(1)
Remove wing nut (1) and tag and remove negative cable (2).
(2)
Remove wing nut (3) and tag and remove positive cable (4).
(3)
Loosen nut (5) and remove terminal (6).
(4)
Loosen nut (7) and remove terminal (8).
(5)
Remove four screws (9) and lockwashers (10) and remove battery holddown (11).
WARNING
Lead acid batteries contain a strong acid. This acid can cause severe skin burns. Handle
battery only with proper lifting strap. Wear protective clothing and eye protection.
(6)
Remove battery (12).
(7)
Inspect cables on batteries and refer to Appendix F for procedures to manufacture new cables as needed.
(8)
Install battery (12).
(9)
Install battery holddown (11) and secure with four screws (9), and lockwashers (10).
(10)
Install terminal (8) and tighten nut (7).
(11)
Install terminal (6) and tighten nut (5).
(12)
Install positive cable (4) and secure
(13)
Install negative cable (2) and secure with wing nut (1).
Change 1
3-110