TM 5-4310-379-14
4-15.
Oil Distribution System (Cont).
b.
Repair. (figure 4-13).
NOTE
Oil distribution system removed for repair, see para. a. above.
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and property. Avoid
repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100-138°F (38-60°C).
(1) Clean all parts with dry cleaning solvent, and dry thoroughly.
(2) Inspect retainer (1) and replace if bent or otherwise damaged.
(3) Inspect screen (2) and replace if ripped or otherwise damaged.
(4) Inspect cover (3) and replace if dented or otherwise damaged.
(5) Inspect pipe (5) and pipe support (4) and replace if cracked or otherwise damaged.
FOLLOW-ON MAINTENANCE
Install oil pan (para. 4-14).
Change 1