TM 5-4310-451-14
5-52. INJECTOR RACK CONTROL LEVER ADJUSTMENT (Cont).
10.
Check for correct left-front injector rack control lever adjustment as follows:
(a)
While holding governor control lever (9) in RUN position, ensure that injector control rack (10) is free to
rotate slightly in a clockwise and counterclockwise direction.
(b)
While again holding governor control lever (9) in RUN position, press downward at end of injector control
rack (10). End should spring upward slightly as pressure Is released.
11.
If checks performed in step 10 indicate adjustment is not correct, repeat steps 5 through 9.
TA705046