TM 5-4310-451-14
5-52. INJECTOR RACK CONTROL LEVER ADJUSTMENT (Cont).
NOTE
Left-front and right-front Injector rack control levers have been adjusted. DO
NOT change adjustment setting on these two levers.
Perform following steps to adjust remaining four Injector rack control levers.
16. Loosen four remaining locknuts (1).
17.
Rotate and hold left injector control tube (7) in full-fuel position.
18.
Perform step 10 for each of two Injector rack control levers (8). Adjust as necessary.
LEFT
19.
Rotate and hold right injector control tube (7) in full-fuel position.
20.
Perform step 10 for each of two injector rack control levers (8). Adjust as necessary.
RIGHT
TA705048
5-173