TM 5-4310-451-14
5-52. INJECTOR RACK CONTROL LEVER ADJUSTMENT (Cont).
3.
Loosen three locknuts (1) and screws (2) on left injector control tube (7).
4.
Check that all six injector rack control levers (8) are loose on left injector control tube (7).
LEFT
5.
Place speed control lever (11) in maximum speed position.
6.
Rotate governor control lever (9) to RUN position and hold in place with light finger pressure.
7.
Rotate screw (2), on left-front injector rack control lever (8), inward until a slight movement of governor control
lever (9) is felt.
8.
Release governor control lever (9).
9.
While holding screw (2), tighten locknut (1).
TA705045