TM 5-4310-452-14Table 3-1. Operator Troubleshooting Procedures (Con't).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION10. OIL CONSUMPTION TOO HIGH.Check to see if compressor unit is level.Adjust compressor unit to within 15° of level end-to-end (see paragraph 2-12).11. OIL LEVEL READING ERRATIC.Check to see if compressor unit is level.Adjust compressor unit to within 15° of level end-to-end (see paragraph 2-12).3-5