the air pressure gauge, relief valve, lines and
reaches the high limit, thereby unloading the
fittings.
to the load limit, the valve releases pressure
b. Installation. Installation is the reverse of
from the suction valve unloaders, thereby
removal.
allowing the suction valves to function nor-
really.
3-117. Air Pressure Gage and Compressor
Relief Valve, lines and Fittings
Open air drain valve (66, fig. 3-8) to relieve
a. Removal. Refer to figure 6-84 and remove
pressure and moisture from air receiver tank.
Section XXI. ALCOHOL DISPENSER, MASTER AIR VALVE,
LINES AND FITTINGS
3-120. Alcohol, Dispenser, Master Air
Valve, lines and Fittings
This section covers removal and installation
instructions for the alcohol dispenser, lines
a. Removal. Remove the alcohol dispenser,
and fittings including the master air valve.
its lines and fittings, and the master air valve
b. Installation. Installation is the reverse of
removal.
Figure 3-35. Alcohol dispenser, master
air valve, lines and fittings
removal and installation.