99. Magnetic Switch
(1) Unscrew the two magnetic switch terminal screws and disconnect the battery cable (4), wire assembly (5)
from ammeter to magnetic switch and starter cable (8) from the switch terminals.
(2) Disconnect the wire assembly (6) from starting switch to magnetic switch and ground wire assembly (7)
from the coil terminals of the switch.
(3) Remove the four hex head bolts (1), cap screws (10), and lockwashers (2 and 11) and lift the magnetic
switch from the side of the battery box.
1 Bolt, hex hd, 1/2-13 x 1% (3 req)
6 Wire assembly, starting switch
2 Lockwasher, 1/2 (3 req) to magnetic switch
7 Wire assembly, ground
3 Magnetic switch
8 Starter cable
4 Battery cable
9 Bond strap
10 Cap screw, hex hd, special
netic switch
11 Lockwasher, special (2 req)
Figure 38. Magnetic switch installed.
b.
(1) Attach the magnetic switch to the side of the battery box with the four hex head bolts (1), cap screws (10),
and lockwashers (2 and 11). Note that the longer bolt (10) and external toothed lockwashers (11) also
serve to attach the bond strap (9).