Table 2-2. Troubleshooting
Malfunction
Test or Inspection
Corrective Action
1.
Air receiver pressure excessive.
STEP 1. Check for inaccurate air pressure gauge (TM55-1905-223-24-18).
Replace gauge (TM 55-1905-223-24-18).
STEP 2. Check for defective pressure switch.
Replace switch (TM 55-1905-223-24-18).
2.
Compressor knocks.
STEP 1. Check for loose compressor valve assemblies.
Secure if needed.
STEP 2. Check for a loose pulley (sheave).
Secure if needed.
STEP 3. Check for inadequate crankcase lubrication.
Add oil if needed.
3.
Compressor loads and unloads excessively (RPMs fluctuate).
STEP 1. Incorrect speed due to belt slipping.
STEP 2. Check for excessive system air leakage from fittings, piping, or air tank.
Locate air leaks and correct as required.
STEP 3. Check for defective unloaders.