TM 9-4310-394-13
4-15.
BELT GUARD REPAIR AND REPLACEMENT. - Continued.
b.
Cleaning.
(1)
Remove all build up of dirt, oil, and debris from all surfaces.
WARNING
Serious injury can result in breathing fumes of dry cleaning solvent. Serious injury or death
can result from explosion of fumes from solvent. When using this solvent:
Clean parts in a well ventilated area.
Avoid inhalation of solvent fumes and prolonged exposure of skin to
cleaning solvent. Wash exposed skin thoroughly.
Do not use near open flame or excessive heat. Flash point of solvent is
100° F to 1380 F (38° C to 59° C).
Wear eye protection when blowing solvent from parts. Air pressure
should not exceed 30 psig (2. 1 kg/cm2).
(2)
Clean all metallic parts with a clean soft cloth or a medium bristle brush, and cleaning solvent.
(3)
Allow parts to dry.
c.
Inspection.
(1)
Inspect all metal parts for cracks or bends.
(2)
Check all fasteners for damaged threads.
d.
Repair.
Repair is limited to replacement of parts found defective during inspection.
e.
Installation.
(1)
Install lower belt guard (15), gasket (23), two screws (20), two flat washers (21), and two lock washers
(22).
(2)
Install bracket (19), two screws (16), two lock washers (17), and two flat washers (18).
(3)
Install upper belt guard frame (14), two screws (4), two lock washers (5), and two flat washers (6) onto
lower belt guard frame (15).
(4)
Install rubber mount (13), rubber mount (12), bracket (11), bracket (10), washer (9), screw (8), and nut
(7).
(5)
Install four screws (1), four lock washers (2), and four flat washers (3) onto upper belt guard frame (14).
4-20 )/ (4-21 Blank)