TM 9-4310-397-14
Table 4-1. Preventive Maintenance Checks and Services for 16MS125
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
1
Quarterly Compressor Air Intake,
Service compressor air cleaner as
Compressor Air Cleaner follows:
a. Open access doors (1).
b. Remove wing nut (2), flat washer
(3), banjo fitting (4), weather
hood (5), and filter (6).
c. Inspect filter (6) for any visible
Filter damaged or
damage or restriction such as dirt
restricted.
accumulation.
d. Clean or replace filter.
e. Install filter (6), weather hood
(5), banjo fitting (4), flat washer
(3), and wing nut (2). Be sure
larger end of banjo fitting is
toward weather hood.
f. Close access doors (1).
4-12