TM 1-1500-204-23-104-6. INSTALLATIONINSTRUCTIONS/PREPARATIONFORUSE. - ContinuedFigure 4-7. Compressor Oil Checking, Draining, and Filling(f)Close drain valve (6) and remove pipe.(g)Wrap antiseize tape (item 1, section II, appendix E) around the drain valve plug (5) threads.(h)Clean the drain valve (6) with a wiping rag (item 2, section II, appendix E) and install the drain valveplug (5).(i)Install approximately 20 quarts of lubricating oil (item 4, section II, appendix E) or until oil is visible inelbow (2).(j)Check condition of preformed packing (3). If cut or damaged in any way, replace it.(k)Clean the adapter (4) with a wiping rag (item 2, section II, appendix E) and install oil filler cap (1).4-8