Figure 33. Starter repair.
and the commutator end frame assem-
between the leads of the connector and
bly. If the lamp lights, the brush
their respective pin sockets. Failure
holder is grounded and the commu-
of the lamp to light indicates an open
tator end frame assembly must be re-
circuit and the defective electrical re-
placed. Test between the grounded
ceptacle connector must be replaced.
brush holder and commutator end
Test between the leads of the electrical
frame. If the lamp fails to light, the
receptacle connector. If the test lamp
lights, a short exists and the connector
brush holder is defective and the com-
must be replaced. Test between each
mutator end frame assembly must be
replaced.
lead and the body of the electrical re-
ceptacle connector. If the lamp lights,
c. Reassembly and Installation.
a grounded condition exists and the
(1) Refer in figure 32 and reassemble the
connector must be replaced.
(17) Test the commutator end frame as-
sembly with a test lamp circuit. Test
between the insulated brush holder
63
AGO 8166A