Table 1. Tabulated Data (For Model 60CAW20HM-2)
Bore and Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5/8 x 2 first stage (2 cyl); 1-3/4 x 2 second stage
CU FT/REV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01252
Air Receiver Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 psi at -25° to +450°F
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..9.3 CFM
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6.5 CFM
Crankcase capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 pint
Shipping weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
282 lbs
Overall Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39" x 22" x 52"
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 or 230 volts, 60 cps, single phase
2.1. INSTALLATION
3.1. LOCATION AND MOUNTING
Installation should be accomplished on a solid,
level base, preferably concrete, with at least 14
inches clearance at the belt guard assembly. Figure
2.1 shows drilling dimensions for bolting or lagging
down through bolt holes in the base feet. Shims should
be used where the base is uneven. Base feet should
never be pulled down to the base as this results in
abnormal vibration.
Figure 2.1 Drilling Dimensions for Mounting
4.1. HEAT COIL SELECTION (See figure 3.1)
The magnetic motor starter contains two overload
heat coils. One is for 115 volt service and the other
is for 230 volt service.
Install the correct heat coil
on the thermal overload (5, fig. 7). Secure the
other heat coil inside the magnetic motor starter box
for possible future use.
5.1. ELECTRICAL CONNECTIONS
Ascertain that available electrical service is 115
or 230 volts, 60 cps, single phase. Shut off electri-
cal service and make wiring connections shown in
figure 4.1. Be sure that V, M, and W terminal wiring
corresponds to available voltage.
CAUTION
Figure 3.1 Magnetic Motor Starter
Do not allow electrical service to be turned on until crankcase has been filled with oil.
F i g u r e 4 . 1 E l e c t r i c a l W i r i ng
2 . 1