TM 5-4310-356-14
WARNING
WARNING
Dry cleaning solvent, P-D-680,
dangerous.
Before performing
used to clean parts is potentially
any maintenance, or adjustments,
dangerous to personnel and
be sure the electrical power has
property. Use in a well ventilated
been turned off. Never depend on
area as the fumes are dangerous
the ON-OFF switch. Turn power
if inhaled. Avoid repeated and
off at the source.
prolonged skin contact. Do not
use near open flame or excessive
heat. Flash point of solvent is
100 . -138 . (38 . -59 .).
F
F
C
C
Section III. TROUBLESHOOTING
3-6. Troubleshooting.
3-5. Scope.
a. This manual cannot list all possible malfunctions
This section contains troubleshooting or
that may occur or all tests or inspections, and corrective
malfunction information and tests for locating and
actions. If a malfunction is not listed or is not corrected
correcting most of the troubles which may develop in the
by listed corrective actions, you should notify higher
air compressor. Each malfunction or trouble symptom
level maintenance.
for an individual component, unit, or system is followed
b.
Table 3-2 lists the common malfunction that you
by a list of tests or inspections necessary for you to
may find during the operation or maintenance of the air
determine probable causes and suggested corrective
compressor or its components. You should perform the
actions for you to remedy the malfunction.
tests, inspections and corrective actions in the order
listed.
3-5