TM 5-4310-362-14
ELECTRIC MOTOR (cont)
LOCATION/ITEM
ACTION
REMARKS
7. Belt guard cover (8)
Install
8. Conduit (9)
Connect to conduit box (10).
9. Starter wires (11)
a. Connect to motor wires.
b. Starter wire from T2 terminal
of starter is joined with motor
wires T1, T3, T5
c. The other starter wire is con-
nected to motor wires T2,
T4 and T8.
d. Double check wiring. Incor-
rect wiring will cause de-
ective operation of motor.
10. Conduit box cover
Install
11. Main power
Connect
MOTOR LEADS ARE MARKED
WITH WIRE DESIGNATION
12. Drain cock on air tank
Open until motor starts, then
A properly wired motor will start up
close again.
and turn counterclockwise as viewed
from the pulley end.
9-15/(9-16 blank)