TM 5-4310-362-14
AIR RECEIVER AND AIR DISCHARGE SYSTEM
LOCATION/ITEM
ACTION
REMARKS
10-5. DISASSEMBLY
1. Main power
Disconnect
To eliminate electrical shock hazard.
To prevent accidental startup of com-
pressor.
2. Drain cock (1)
Open to release air, then un-
Air in tank must be discharged before
screw from tank (2).
system can be disassembled.
3. Pressure switch (3)
Remove
4. Safety relief valve (4)
Remove
5. Pipe nipples & tee (5)
Unscrew
6. Check valve (6)
Unscrew
(Model 20-904)
6A. Check valve (6)
a. Disconnect unloader tube
(Model 20-911)
b. Unscrew
7. Gage (7)
Unscrew
8. Inflator gage (8)
Unscrew from hose (9).
9. Hose (9)
Unwind and unscrew from globe
valve (10).
10. Globe valve (10)
Unscrew
10-4 Change 1