TM 5-4310-368-14
4-40.
4TH STAGE SEPARATOR
This task covers:
a.
Inspection
b.
Service
c.
Repair and Replacement
INITIAL SETUP
Applicable Configurations
All
Equipment Condition
Paragraph
Condition Description
Side Access Panel Removed
General Safety Precautions
Do not attempt to open or service 4th stage separator until all pressure has been
released. Compressor must be shut down and all pressure released by the
condensate drain valve. Note 4th stage pressure gage reading. Gage reading
must be "0."
a.
Inspection. Inspect 4th stage separator and all tubing for leaks, loose fittings or damage. Repair or replace
defective components.
b.
Service. Replace filter element every 1000 hours of operation. Refer to direct support maintenance for
procedure.
c.
Repair and Replacement. Refer to direct support maintenance.
4-43