TM 5-4310-368-14
4-47.
This task covers:
a.
Removal
b.
Testing
c.
Installation
INITIAL SETUP
Applicable Configurations
All
Equipment Condition
Paragraph
Condition Description
Battery Disconnected
a.
Removal
(1)
Disconnect wire harness at two places. Mark wire for reassembly.
(2)
Remove two nuts, two washers and saddle clamp. Remove ammeter.
b.
Testing. Apply known current to ammeter. Observe reading on ammeter. Ammeter reading should be within
5% of known current. Replace defective ammeter.
c.
Installation
(1)
Position ammeter into hole in instrument panel.
(2)
Assemble saddle clamp, two washers and two nuts to studs on back of ammeter. Secure nuts.
(3)
Connect wire harness at two places.
4-47A.
GAGES
This task covers:
a.
Removal
(1)
Disconnect pressure tube.
(2)
Disconnect 2 each mounting screws.
(3)
Remove gage from panel.
Change 1
4-48