TM 5-4310-368-14
4-43.
INSTRUMENT PANEL
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Applicable Configurations
All
Equipment Condition
Paragraph
Condition Description
Enclosure Roof Panel Removed
Battery Disconnected
General Safety Precautions
Make sure compressor is shut down and all pressure relieved before
disconnecting gage tubing.
a.
Removal
(1)
Disconnect all pressure tubing at rear of instrument panel.
(2)
Disconnect main wire assembly at 25 places. Make a note of location of wiring connections.
(3)
Disconnect panel lamp wire from switch.
(4)
Loosen and remove four bolts, four nuts and four lock washers. Remove instrument panel.
b.
Installation
(1)
Position instrument panel assembly against frame uprights.
(2)
Align bolt holes in panel mounts with bolt holes in frame uprights.
(3)
Install and secure panel to frame uperights with four bolts, four nuts and four lock washers.
(4)
Connect all pressure tubing to rear of instrument panel.
(5)
Connect main wire assembly at 25 places.
(6)
Connect panel light wire to switch.
4-45