TM 5-4310-36814
INITIAL SETUP
Applicable Configurations
All
General Safety Precautions
WARNING
Make sure all air pressure has been relieved from separator before disconnecting any air
line. Note 4th stage pressure gage on instrument panel. Gage reading must be "0."
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open flame
or excessive heat. Flash point of solvent is 100 (38 ) - 138 (59 ).
F
C
F
C
a. Removal
(1) Disconnect three tubes from separator assembly.
(2) Loosen and remove two bolts, nuts and four straps. Remove separator assembly from frame.
b. Disassembly
(1) Remove fittings from top of separator assembly.
(2) Remove one fitting from bottom of separator assembly.
(3) Secure body of separator in a vise which is equipped with soft jaws.
(4) Screw two 3/8-16 x 2" socket head screws into tapped holes in bottom plug. Unscrew bottom plug.
(5) Remove O-rings from bottom plug.
(6) Screw two 3/8-16 x 2" socket head screws into tapped holes in top plug.
(7) Remove screw and deflector plate.
(8) Remove spray nozzle.
(9) Remove upper deflector, filter retainer and filter element.
5-41