TM 5-4310-368-14
(4) Assemble and secure three tubes to separator assembly.
5-21.
AIR RECEIVER
This task covers:
a. Removal
d. Inspection
b. Disassembly
e. Reassembly
c.
Cleaning
f.
Installation
INITIAL SETUP
Applicable Configurations
All
Equipment Condition
Paragraph
Condition Description
Enclosure Door Removed
Enclosure End Panel Removed
General Safety Precautions
WARNING
Relieve all pressure before attempting to disconnect any air line. Open receiver dump
valve on instrument panel.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open flame
or excessive heat. Flash point of solvent is 100 (38 ) - 138 (59 ).
F
C
F
C
a. Removal
(1) Remove two straps, four nuts and four lock washers.
(2) Disconnect three tubes.
(3) Attach lifting sling.
(4) Lift air receiver out of frame.
5-43