TM 5-4310-385-13
SECTION III. OPERATION UNDER USUAL CONDITIONS
2-5. PREPARATION FOR USE.
a.
The air compressor is shipped completely assembled with all components in place, secured to a bottom skid,
within a wood crating enclosure.
b.
If compressor is to be used as a portable unit, compressor can be left bolted to bottom skid. Compressor and
skid must be placed on firm level ground or flooring to minimize vibration and ensure proper operation.
c.
For permanent installation, the manufacturer recommends leaving the compressor bolted to the bottom skid and
installing the skids to a level surface. The base should be at least 12" from any wall.
CAUTION
If skids are removed, do not eliminate space between the base and a foot by
drawing the foot down. This would stress the tank foot and result in abnormal
vibration and possible damage to the tank.
d.
If flooring or base is not completely level, shims must be used.
e.
Compressor must be located in a clean, well ventilated dry room so compressor receives an adequate supply of
fresh, clean, cool and dry air. Allow sufficient space around the compressor so that it is accessible from all sides for
maintenance.
f.
For proper cooling, ensure that no object will obstruct the flow of air through the belt guard to the fan bladed
flywheel.
Proper Air Flow
2-7