TM 5-4310-451-14
5-49. EXHAUST VALVE CLEARANCE ADJUSTMENT (Cont).
5.
Rotate pushrod (2) until slight drag is felt on feeler gage.
6.
Remove feeler gage and tighten locknut (3) while holding pushrod (2).
7.
Check clearance with feeler gage. If adjustment is correct, 0.015 In. (0.381 mm) feeler gage will pass freely, but
0.017 in. (0.432 mm) feeler gage will not.
FOLLOW-ON TASKS:
Install rocker arm covers (see paragraph 4-29).
TA705040
5-165