Figure 84. Adjusting cutout relay point opening.
at 25.5 volts. If the contacts do not close at the specified voltage, disconnect the regulator. Measure the air
gap between the armature and the center of the core with the contacts closed (fig. 88). The air gap should
be 0.017 inch. Loosen the adjusting screws at the back of the relay and raise or lower the armature as
191