Figure 85. Adjusting cutout relay closing voltage.
required. Tighten the screws after adjustment. Measure the contact point opening with the contacts open
(fig. 84). The contact point opening should be 0.32 inch. Bend the upper armature stop with an offset
screwdriver to adjust the contact point opening as required. Connect the regulator (fig. 82) and check the