Figure 88. Adjusting voltage regulator setting.
Starting Motor

Compressor Air Truck-Mounted Gasoline-Driven 210 Cfm Le Roi Model 210G1 Page Navigation
  189    190    191    192    193  194  195    196    197    198    199  
img
. . .
Figure 89. Checking current regulator setting.
g. Installation. Refer to paragraph 91b.
Section VIII. STARTING MOTOR AND MAGNETIC SWITCH
198. Starting Motor
a. Description. The 24-volt starting motor is equipped with a Bendix-type drive which automatically meshes with the
flywheel ring gear for starting and unmeshes after starting. The Bendix-type drive is housed in the drive housing. The
armature shaft rotates in three bronze bushings in the commutator-end frame, center bearing and drive housing. The four
brushes are held in brush holders which are an integral part of the commutator-end frame. Torsion springs provide the
proper brush pressure in the commutator. Field poles support the four-coil field coil assembly and strengthen and improve
distribution of the magnetic field.
b. Removal. Refer to paragraph 93a.
c. Disassembly (fig. 90). Detach the commutator-end frame (36) by removing the cover band (29), disconnecting the
field coil leads from the brush holders, and removing the through-bolts (39) and lockwashers (38). Tap the commutator-end
196