d. Install Engine Generator and Stator Housing .
(1)
Install stator housing (4, Figure 5-8) into engine flywheel (6, Figure 5-5).
(2)
Install cap screw (3, Figure 5-8).
NOTE
Insure stator wires are installed in original location.
(3)
Install engine generator stator (2), tapping screws (1) and tighten.
(4)
Install wire (5) into clamp (6).
(5)
Install engine flywheel (6, Figure 5-5).
(6)
Install flat washer (5) and plain hexagon nut (4).
(7)
If damaged, install new plain encased seal (7) on cooling fan case (3).
(8)
Install cooling fan case (3).
(9)
Install lock washer (2), cap screws (4) and tighten.
(10)
Install engine intake air cleaner (reference para. 4-17).
(11)
Install recoil starter (reference para. 4-18).
(12)
Perform engine generator voltage test (reference para. 5-6, a.). If voltage is now in accordance with
Table 5-3, repair is complete. If not, replace stator housing (reference para. 5-6, b.) and retest.
(13)
Connect wires (5, Figure 5-8) that were removed from current limiter (8).
e. Install Current Limiter .
(1)
Install current limiter (8).
(2)
Install ground wires (9), cap screws (10) and tighten.
(3)
Connect wire connector (7) to current limiter (8).