TM9-4310-396-13
MAINTENANCE OF ENGINE GENERATOR
5-6.TEST/REPLACE ENGINE GENERATOR.
This task covers:
a.
Test
c.
Installation
b.
Removal
INITIAL SETUP
Tools
Equipment Conditions:
General Mechanics Tool Kit
Engine stopped, para. 2-6.8
Materials/Parts
None
a.
Test Engine Generator.
NOTE
The diesel engine must be running for steps (1), a. through (1), f.
(1) Engine generator voltage test.
(a) Disconnect engine generator output (1, Figure 5-4) from current regulator with engine generator (2) still
attached to engine.
(b) Connect engine generator output (1) to volt/ammeter.
Figure 5-4. Generator Output Diagram.
5-11