TM9-4310-396-13d.TestAssembledEngineStarterMotor.NOTETo insure starter motor operative after installation of parts, perform a no-load test.(1) No-load test: Fix starter motor on test bench. Connect wiring Figure 5-2) to the motor. Close switch.Current flows through motor, which will rotate at no-load. Measure working current, voltage, and motorrevolutions.Figure 5-3. EngineStarterMotorWireDiagram.(2) Refer to Table 5-2 for Starter Motor Maintenance Standards.Table 5-2 No Load TestNo Load Current (Amps)60 MaximumNo Load Voltage11.5 VoltsNo Load RPM7,000 Minimum5-10