TM 9-4310-397-14
b.
Testing.
(1)
Disconnect wire leads (1), and tag (item 18, section II, appendix E)for testing.
(2)
Using a multimeter set to measure resistance, check resistance across HOURMETER terminals.
Resistance indicated should be between 0.3 - 0.4 K OHM's.
(3)
If no reading is indicated, HOURMETER is defective. Replace HOURMETER.
c.
Installation.
(1)
Install HOURMETER (Figure 4-32, 2) through front panel.
NOTE
Terminal hardware is supplied with most components and cannot be purchased separately.
Retain all hardware if original component is not being replaced. If component is being replaced,
use new hardware supplied.
(2)
Install bracket (5), lock washer (4), and hex nut (3) to HOURMETER (2) and tighten.
(3)
Refer to tags and wiring diagram Figure 4-3. Connect leads (1).
(4)
Connect battery cables to batteries. See paragraph 4-49.
(5)
Close control panel door.
4-95