TM 9-4310-397-14
4-48. MISCELLANEOUS WIRES AND CABLES TESTING AND REPLACEMENT.
This task covers:
a.
Removal
b.
Testing
c.
Repair
d.
Installation
INITIAL SETUP
Tools:
Equipment Conditions:
General Mechanics Tool Kit
Battery cables disconnected from batteries.
Item 1, Section III, Appendix B
(See para 4-49.)
Shop Equipment Electrical
Item 3, Section III, Appendix B
a.
Removal.
(1)
Remove hex headscrew (Figure 4-45, 1), and lock washer (2). Discard lock washer.
(2)
Remove hex head screw (3), two flat washers (4), and self locking nut (5). Discard nut.
(3)
Remove cable (6).
(4)
Remove pan head screw (7), nut (8), and wire (9).
Figure 4-45. Miscellaneous Wires and Cables
b.
Testing.
(1)
Using a multimeter, check continuity between terminal lugs (10) and (11). Continuity should be indicated. If no
continuity is indicated, replace cable.
(2)
Using a multimeter, check continuity between terminal lugs (12) and (13). Continuity should be indicated. If no
continuity is indicated, replace wire.
4-123