TM 9-4310-397-14
(8)
Disassemble battery box as follows:
(a)
Drill out rivets (1) remove information plate (2) from battery cover (3).
Figure 4-47. Battery Box
(b)
Remove grommets (4) and (5) from battery box (6).
(c)
Drill out rivets (7) from latches (8). Remove latches.
(d)
Remove four hex head screws (9), lock washers (10), and flat washers (11).
b.
Testing.
NOTE
Batteries supplied with unit are factory sealed lead acid type that require no water, won't
corrode or leak and require no terminal cleaning.
(1)
Using a voltmeter set to measure voltage, check voltage across terminals.
4-127