TM 9-4310-397-14
Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
10 -
c.
Inspect the old compressor oil
Cont
filter (32) for any dark brown,
sticky substance on the inside
surface. This indicates that a
varnish condition exists in the oil
system and the following cleaning
procedures must be performed.
Discard oil filter. Contact your
local environmental officer for
guidance on how to dispose of oil
filter in accordance with local
regulations.
(1) Remove oil filler cap (33).
(2) Remove drain valve plug
(34).
(3) Install a pipe (section II,
appendix D) into drain valve
(35).
(4) Place a pan (section II,
appendix D) under pipe end.
(5) Open drain valve (35) and
wait for all lubricating oil to
drain out. Contact your local
environmental officer for
guidance on how to properly
dispose of lubricating oil in
accordance with local
regulations.
(6) Close drain valve (35).
(7) Install a mixture of two quarts
Thermo-Solve concentrate
(item 16, section II, appendix
E) and approximately 18
quarts lubricating oil (item 4,
section II, appendix E).
(8) Check condition of preformed Preformed packing
packing (36). Replace if
damaged.
damaged.
4-19