TM 9-4310-397-14Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - ContinuedLocationItem No.IntervalProcedureNot Fully Mission Capable If:Item toCheck/Service10 -c.Inspect the old compressor oilContfilter (32) for any dark brown,sticky substance on the insidesurface. This indicates that avarnish condition exists in the oilsystem and the following cleaningprocedures must be performed.Discard oil filter. Contact yourlocal environmental officer forguidance on how to dispose of oilfilter in accordance with localregulations.(1) Remove oil filler cap (33).(2) Remove drain valve plug(34).(3) Install a pipe (section II,appendix D) into drain valve(35).(4) Place a pan (section II,appendix D) under pipe end.(5) Open drain valve (35) andwait for all lubricating oil todrain out. Contact your localenvironmental officer forguidance on how to properlydispose of lubricating oil inaccordance with localregulations.(6) Close drain valve (35).(7) Install a mixture of two quartsThermo-Solve concentrate(item 16, section II, appendixE) and approximately 18quarts lubricating oil (item 4,section II, appendix E).(8) Check condition of preformed Preformed packingpacking (36). Replace ifdamaged.damaged.4-19