TM 9-4310-397-14
Table 4-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
10-
(9) Clean the adapter (37) with
Cont
a wiping rag (item 2, section
II, appendix E) and install oil
filler cap (33).
(10)
Install new compressor oil
filter (32) (item 2, section IV,
chapter 4).
(11)
Operate the compressor
under normal conditions for
40 to 60hours. This will
allow the oil/solvent mixture
sufficient time to dissolve
and suspend the varnish in
the system.
(12)
Place a pan (section II,
appendix D) under pipe end.
(13)
Shut down the compressor
and while the oil is still hot,
open drain valve (35) and
wait for all lubricating
oil/solvent mixture to drain
out. Contact your local
environmental officer for
guidance on how to properly
dispose of lubricating
oil/solvent mixture in
accordance with local
regulations.
(14)
Close drain valve (35) and
remove pipe.
(15)
Carefully remove and
discard oil filter (32).
(16)
Open access doors (38).
(17)
Tag (item 18, section II,
appendix E) and disconnect
hoses as necessary to
remove oil separator cover
(39).
4-20